Recently i used Schneider PLC to learn ladder programming and i saw that
PLC has Modbus communication.I did some research about this communication
protocol and thought you also may have interest about this industrially used
communication protocol.
Modbus is a serial communication protocol developed by Modicon.😮😮
Well, What is serial communication and what is a Protocol ???
Serial communication is process of sending/receiving data ,one bit at a time sequentially(or in an order).This definition simply gives the definition for parallel communication,which is two or more bits at a time simultaneously along multiple channels.
Communication protocol is a system of rules that is applied
to communication process/system to transmit data along any communication
channel.
These rules are used to define ...
- Recovery methods. (due to
Errors occur in the communication)
- Data type used in the
communication.
- Address formats for data
exchange.
- Flow control of data.
- Sequence control of
data,Etc.
The common language used by all Modicon devices(eg. PLC,VSD) is Modbus
protocol.This protocol defines the message structure which is used to communicate
between controllers,monitoring devices,Etc and therefore this is a messaging
protocol.There can be seen so many protocols used in communication such as file
transfer[FTP],Transmitting structured text(Hypertext)[HTTP],Etc.So now we know
that Modbus is serial messaging protocol used in Modicon devices.
Modbus is Application layer protocol positioned at level 7 of the OSI
model.😮😮😮 Hell ! what is that ???
The ISO(International Organization of Standardization)-OSI(Open System
Interconnection) model is 7 layered architecture defined for a
communication system.
Now I will give very rough idea about the OSI model.
- The physical layer converts the digital/analog bits into electrical
signal or optical signals.It defines transmission medium(Copper
cables,Bluetooth.Etc).
- The Data link layer
synchronizes the information which is to be transmitted over the
physical layer.
- The Network layer routes the
signal through different channels from one node to other and It acts as a
network controller. It manages the Subnet traffic.
- The Transport layer decides
if data transmission should be on parallel path or single path and the
functions such as Multiplexing, Segmenting or Splitting on the data are
done by this layer.
- The Session layer
manages and synchronize the conversation between two different
applications.
- The Presentation layer takes
care that the data is sent in such a way that the receiver will understand
the information (data) and will be able to use the data.
- The Application layer is
responsible for interacting with various software applications and
implement communication components for all of them. Mail services,
directory services, network resource etc are services provided by
application layer.
Each layer has set of defined protocols used for different applications.
So, Modbus protocol is application layer messaging protocol which provides Client/Server communications between Modicon devices.
In the next post i will go more detail into technical side of Modbus protocol.
If you have any doubt please leave a message.Thanks.
Nice blog... Thanks for sharing details on Modbus Protocol. I found best information on Modbus protocol.
ReplyDeleteThanks !